MATON 500 is a cement based mixture designed for repair works which require quick hardening ability; monocomponent, polymerizable, resistant to hydrolysis and breaking, smooth. The product conforms to the requirements of the 039-2000 (TS 11140-1993) standard: “Adhesives – cement based (hydraulic conjunction), suitable for glazed, ceramic, and floor tiles”. More smooth and more resistant.

Fields of Application

This repair mixture can be applied in the following areas:

  • mounting works for hatchway ladders;
  • repair of walls in sewage installations and hatchways;
  • repair of concrete elements of railway tracks and platforms;
  • repair and restoration of concrete surfaces provided for vehicle traffic

Advantages

  • achieves high strength within short period of time for transport, and vehicle traffic on the treated surface may be allowed in one hour after application;
  • reduces to minimum the risk of cracks due to quick hardening;
  • the product is mixed with water only, easily takes the form of moulds when cast in molds;
  • shows high fluidity properties;
  • does not form cracks, waterproof;
  • resistant to freezing and heating;

Method of application

Preparation of the surfaces. Cement based surfaces should be rigid, clean and dust-free. The surface should be totally free of any fat, rust, paraffin, and other substances deteriorating adhesive force. Edges of the surfaces restored by means of breaking should be cut smooth, rust existing on equipment should be removed, new equipment should be added, if necessary. In case there is spilled water on the surface, it should be sponged up, or the water flow should be stopped using İzoKontakt 1. Provide water saturation of the surface to be treated with the mixture, however there should not be free water remained on the surface.

Preparation of the mixture. Pour appropriate amount of water measured with a measuring device into the mixing container. Gradually add the MATON 500 product and prepare the mixture for 4 minutes using 400-600 RPM mixer. Mix again in approximately 4 minutes during 30-minute period, bringing the product to conditions ready for application. 

Application. Spread the prepared mixture over the surface to obtain a 10 – 50mm thick layer. Open the moulds in 15 minutes. In case a layer thickness above 50mm is required, mix the MATON 500 product with fine filler (5-10mm) in 1/2 proportion (1kg of filler per 2 kg of the powder).

Recommendations. The MATON 500 repair mixture should be used within 7 minutes at +200C temperature. Application and reaction rate of cement based systems can be affected by the ambient and soil temperatures and other conditions, including air humidity. Low temperature elongates the hydration period, and results in increase of the drying time and effective life. To provide full hardening of the material the ambient and soil temperatures should not drop below the specified minimum values. When applying the mixture  with fine fillers the substances should be dry mixed first and then added to the mixing container with water till the water content in this mixture reaches 10%. The MATON 500 product may be applied on the soil. After use all hand tools and devices should be cleaned with water.

Consumption

The required amount of the powder mix consumed to obtain 1mm thickness layer shall be 2 kg/m2.

Shelf Life and Storage Method

The product can be stored during 12 months packed in original sacks in dry and cold conditions. For the short storage period the sacks can be placed one upon the other in three layers. In case of long-term storage the product packages should not be laid one upon another. The product in unpacked sacks should be used within one week provided the required storage conditions are maintained.

Warnings

  • when using the product observe regulations of operational and personnel safety, wear appropriate protective clothing, safety gloves, glasses, and respirators;
  • taking into consideration that the product can cause allergic reactions and itch, take care to avoid contact of its components with skin or eyes, otherwise immediately rinse them with large amount of water and wash with soap;
  • in case you swallow the product, immediately consult a physician;
  • do not keep food products in the areas of the solution application;
  • keep the product away from children;

Warranty and technical support

  • information indicated in technical specifications is based on scientific and experimental data;
  • Matanat А company is responsible for the product quality only;
  • with the exception of cases of works executed under the supervision of the company specialists, Мatanat  А company shall not be liable for any problems occuring due to improper use of the product by other persons;
  • the company reserves the right to make changes in its product in consequence of scientific-and-technical development;